Optische Kohärenzmikroskopie für die Diagnose im Verdauungstrakt : Simulation, Laborexperiment und endoluminales Konzept

DSpace Repositorium (Manakin basiert)

Zur Kurzanzeige

dc.contributor.advisor Plies, Erich de_DE
dc.contributor.author George, Markus de_DE
dc.date.accessioned 2004-12-14 de_DE
dc.date.accessioned 2014-03-18T10:13:41Z
dc.date.available 2004-12-14 de_DE
dc.date.available 2014-03-18T10:13:41Z
dc.date.issued 2004 de_DE
dc.identifier.other 115141197 de_DE
dc.identifier.uri http://nbn-resolving.de/urn:nbn:de:bsz:21-opus-14975 de_DE
dc.identifier.uri http://hdl.handle.net/10900/48690
dc.description.abstract Bösartige Neubildungen (Krebs) lassen sich in frühen Stadien mit deutlich günstigeren Prognosen therapieren, sind dann jedoch auch schwieriger zu erkennen und korrekt zu diagnostizieren. Die Diagnose basiert auf dem Differenzierungsgrad der Zellen, der bislang nur in vitro durch Mikroskopie von Dünnschnitten eines Biopsats nach histologischer Aufbereitung bestimmbar ist. Epitheliale Neubildungen (Karzinome) wären einer Histologie in vivo zugänglich, jedoch können konventionelle Mikroskope einzelne Zellschichten aufgrund der starken Steuung in Gewebevolumina nicht darstellen. Konfokale Mikroskopie und optische Kohärenztomographie sind tomographische Verfahren, bei denen der Anteil gestreuten Lichts an der Bildintensität deutlich reduziert ist und die unter Verwendung von Lichtwellenleitern miniaturisierbar sind. Die optische Kohärenzmikroskopie vereint die Vorteile beider Verfahren, nämlich eine hohe laterale Auflösung aufgrund der Konfokalität und hohe Informationstiefen aufgrund des interferometrischen Kohärenzfilters. Die Bildaufnahme erfolgt lateral bei fester axialer Lage des Kohärenzfilters, weshalb zum Messen des die Bildinformation darstellenden Kohärenzgrades eine Phasenmodulation im Referenzarm des Interferometers eingeführt wird. Diese Arbeit entwickelt in drei Teilen die optische Kohärenzmikroskopie in Richtung eines Systems für die endoskopische in vivo-Histologie. Im ersten Teil wird ein optisches Kohärenzmikroskop im Labormaßstab aufgebaut und die Eignung der Bildgebung für die Anwendung auf Epithelien des Verdauungstrakts untersucht. Bei einer Zentralwellenlänge von 1310 nm und einer Kohärenzlänge von 14,4 µm liegt seine laterale Auflösung bei 1,45 µm, die axiale Auflösung bei 3,0 µm. Bildrasterung und Phasenmodulation im Referenzarm erfolgen piezoelektrisch. Das optische Kohärenzmikroskop erreicht eine im Vergleich zur konventionellen konfokalen Reflexionsmikroskopie um 28 dB bessere Dynamik und ist Aberrationen gegenüber weniger empfindlich. Robuste und für den klinischen Einsatz relevante Algorithmen zum weitestgehend automatisierten Betrieb eines optischen Kohärenzmikroskops werden entwickelt. Die Punktbildfunktion des optischen Kohärenzmikroskops wird als Funktion der Referenzarmlänge vermessen und unter Bezug auf die Autokorrelationsfunktion des Spektrums der Lichtquelle interpretiert. Sie wird unter anderem herangezogen, um Möglichkeiten der Reduktion von Speckles vorzuschlagen. Das objektphasenkorrelierte Streifenartefakt wird erstmals beschrieben. Zur Erfassung der Topologie von Oberflächen wird eine sehr einfache Methode zur Ableitung von hochaufgelösten Isophasenlinien im Abstand einer achtel Wellenlänge vorgestellt. Bei allen Epithelien des Verdauungstrakts können Zellmembranen identifiziert werden. Platten- und Zylinderepithel können anhand der azimutal gemittelten Leistungsspektren von oberflächennahen Bildern voneinander unterschieden werden. Im zweiten Teil werden die mathematischen Grundlagen zur rechnerbasierten Simulation der Bildgebung eines optischen Kohärenzmikroskops erarbeitet. Simuliert wird für jede Bildzeile das Signal der zeitabhängigen, detektierten Intensität sowie die Demodulation dieses Signals. Das Gewebemodell besteht aus beliebig vielen reflektierenden Grenzflächen. Die spektrale Leistungsdichte der Lichtquelle ist als Summe beliebig vieler gaußförmiger Verteilungen modellierbar. Die Simulation wird erfolgreich angewendet, um die Ursache des objektphasenkorrelierten Streifenartefakts nachzuweisen. Neben dem Vergleich mit dem Experiment wird das Ergebnis theoretisch untermauert, was eine verfeinerte Unterscheidung zwischen verfahrensinhärenten und justagebedingten Ursachen des Artefakts erlaubt. Eine Strategie zur Minimierung des kritischen justagebedingten objektphasenkorrelierten Streifenartefakts wird aufgezeigt. Im dritten Teil wird basierend auf den gewonnenen Erkenntnissen ein implementierbares Konzept für ein endoskopisches optisches Kohärenzmikroskop erarbeitet. Eine geeignete konfokale Sonde wird vorgestellt. Sie erreicht mittels eines kardanisch gelagerten, miniaturisierten Rasterspiegels eine Bildrate von 0,5 Hz. Zur elektrooptischen Phasenmodulation mittels eines Lithiumniobatkristalls bei der Frequenz 10 MHz wird eine Impedanzwandlungsschaltung entworfen, um einen leistungsschwachen Oszillator als Treiber einsetzen zu können. Zur Demodulation des hochfrequent phasenmodulierten Interferenzsignals wird eine kostengünstige analoge Schaltung aufgebaut. Neben weiteren Anpassungen an die im Vergleich zum Laboraufbau höhere Bandbreite der Bildaufnahme werden Randbedingungen für den klinischen Einsatz berücksichtigt. de_DE
dc.description.abstract Early therapy of malignant neoplasia (cancer) leads to clearly better survival rates, however, early stage neoplasia are generally harder to detect and diagnose correctly. Diagnosis is based on cellular differentiation (grading), which up to now can only be determined in vitro by microscopy of thin sections of a biopsy sample after histologic processing. Epithelial neoplasia (carcinoma) would be accessible to histology in vivo, but conventional microscopes cannot image single cellular layers because of the strong scattering within tissue volumes. Confocal microscopy and optical coherence tomography are tomographic methods, which effectively filter scattered light that otherwise would contribute to image intensity. They can be miniaturized using optical fibers. Optical coherence microscopy combines the advantages of both methods, i.e. high lateral resolution provided by confocality and long information depths in biological tissue provided by the interferometric coherence gate. Images are acquired in lateral direction at a fixed axial position of the coherence gate. Therefore, a phase modulation has to be employed in the interferometer's reference arm to measure the degree of coherence and thus the image intensity. This three-part work develops optical coherence microscopy towards a system for endoscopic in vivo-histology. In the first part an optical coherence microscope is set up on a laboratory scale to investigate to which degree confocal low-coherence reflectometry can be applied to image epithelial layers of the gastrointestinal tract. With a center wavelength of 1310 nm and a coherence length of 14.4 µm, lateral and axial resolutions are 1.45 µm and 3.0 µm, respectively. Scanning of the sample as well as the phase modulation in the reference arm are performed piezoelectrically. The optical coherence microscope provides a 28 dB improvement in dynamics compared to conventional confocal reflection microscopy and is less sensitive to aberrations. Robust and clinically relevant algorithms for a mostly automated operation of an optical coherence microscope are developed. The point spread function of the optical coherence microscope is measured as a function of the reference arm length and interpreted regarding the autocorrelation function of the light source spectrum. It is, among other techniques, used to propose ways to reduce speckles. The fringe-like artifact related to the object phase is described for the first time. A very simple method to determine surface topologies is introduced, with which highly resolved isophase lines separated by an eighth of the center wavelength can be derived. Cellular membranes can be identified for all epithelial layers of the gastrointestinal tract. Columnar and squamous epithelium can be automatically distinguished based on azimutally averaged power spectra of images recorded close to the surface. In the second part mathematical foundations for the computer-based simulation of the imaging of an optical coherence microscope are worked out. For each line of an image the signal of the time-dependent detected intensity is simulated as well as the demodulation of this signal. The tissue model comprises an arbitrary number of reflecting boundary faces. The spectral power density of the light source can be modelled as a sum of an arbitrary number of gaussian distributions. The simulation is applied successfully to provide evidence for the cause of the fringe-like, object phase-related artifact. Besides being compared to an experiment, the result is substantiated theoretically, which leads to a refined discrimination between two causes of the artifact, one of which is inherent to the imaging method itself while the other is due to alignment issues. A strategy to minimize the critical fringe-like, object phase-related artifact caused by misalignment is shown. In the third part a realizable concept for an endoscopic optical coherence microscope is developed based on the results yielded before. A suitable confocal probe is presented. Using a gimbal-mounted miniaturized mirror for scanning, it achieves an image rate of 0.5 Hz. For an electrooptic phase modulation with a lithium niobate crystal at 10 MHz frequency an impedance-converting circuit is desiged to enable the use of a low-power oscillator to drive the modulation. For the high-frequency demodulation of the interference signal an economical analog circuit is set up. The concept includes additional adaptions to the increased bandwidth of image acquisition, which is significantly higher compared to the laboratory setup. In addition, boundary conditions for a clinical application are taken into account. en
dc.language.iso de de_DE
dc.publisher Universität Tübingen de_DE
dc.rights ubt-podok de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=de de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_mit_pod.php?la=en en
dc.subject.classification Konfokale Mikroskopie , Optische Tomographie , Phasenmodulation , Endoskopie , Verdauungskanal de_DE
dc.subject.ddc 530 de_DE
dc.subject.other in vivo Histologie , optische Biopsie de_DE
dc.subject.other in vivo histology , optical biopsy en
dc.title Optische Kohärenzmikroskopie für die Diagnose im Verdauungstrakt : Simulation, Laborexperiment und endoluminales Konzept de_DE
dc.title Optical coherence microscopy for gastrointestinal diagnosis : Simulation, laboratory experiment and endoluminal concept en
dc.type PhDThesis de_DE
dcterms.dateAccepted 2004-10-28 de_DE
utue.publikation.fachbereich Sonstige - Mathematik und Physik de_DE
utue.publikation.fakultaet 7 Mathematisch-Naturwissenschaftliche Fakultät de_DE
dcterms.DCMIType Text de_DE
utue.publikation.typ doctoralThesis de_DE
utue.opus.id 1497 de_DE
thesis.grantor 12/13 Fakultät für Mathematik und Physik de_DE