Multi-Detektor-System für das hochauflösende Pulverdiffraktometer B2 am HASYLAB (DESY) - Entwicklung, Aufbau und Einsatz eines zeit-effizienten Messsystems zur Strukturanalyse von Pulverproben mit Synchrotronstrahlung

DSpace Repositorium (Manakin basiert)

Zur Kurzanzeige

dc.contributor.advisor Prandl, Wolfram de_DE
dc.contributor.author Kaps, Wolf-Hendrik de_DE
dc.date.accessioned 2001-04-05 de_DE
dc.date.accessioned 2014-03-18T10:08:46Z
dc.date.available 2001-04-05 de_DE
dc.date.available 2014-03-18T10:08:46Z
dc.date.issued 2001 de_DE
dc.identifier.other 090785444 de_DE
dc.identifier.uri http://nbn-resolving.de/urn:nbn:de:bsz:21-opus-2387 de_DE
dc.identifier.uri http://hdl.handle.net/10900/48157
dc.description.abstract Bisher waren für höchstauflösende Pulver-Beugungsexperimente lange Messzeiten an teuren Synchrotronquellen notwendig. Mit dem hier vorgestellten Multi-Detektor-System (MDS) wurde an der Beamline B2 am HASYLAB (DESY) ein entscheidender Schritt zur Erhöhung der Messeffizienzund die Erweiterung der experimentellen Möglichkeiten vollzogen. Das Multi-Detektor-System - vier Diffraktometer in Parallelstrahlgeometrie für höchstauflösende Pulver-Beugungsexperimente in einem kompakten Gerät - erreicht einen maximalen Gewinnfaktor von fast 4 in der Nettomesszeit gegenüber einem konventionellen Diffraktometer. Außerdem ermöglicht es durch die simultane Detektion mehrerer Winkelbereiche die Beurteilung der Datenqualität bereits während der Messung. Das gerätetechnische Konzept des MDS ist durch ein konsequent modulares Aufbauprinzip geprägt. Die Steuerung des MDS ist vollständig in das Bedienungskonzept der Beamline B2 integriert. Alle Prozesse werden über einen Steuerrechner ausgeführt und kontrolliert. Die einheitliche Bedienungsoberfläche ermöglicht dem Nutzer eine kurze Einarbeitungszeit. Der reduzierte Zeitaufwand für die Justierung der vier Analysatoreinheiten durch den synchronen Antrieb trägt wesentlich zur Effizienz des MDS bei. Die Positioniergenauigkeit der Analysatorkristalle liegt bei 0.00034°. Die Winkelstellungen der Antriebe werden mit Präzisionsdrehgebern separat kontrolliert. Aufgrund der austauschbaren Analysatoreinheiten, bestehend aus flachen Si (111)- und Ge (111)- Channel-Cut Analysatorkristallen, kann mit einem Gerät ein Wellenlängenbereich von 0.6 Å (20.7 keV) bis 2.5 Å (4.96 keV) genutzt werden. Weitere Vorteile des MDS sind: die hohe Quantenausbeute der Detektoren, die Integration des MDS in die bestehende Infrastruktur der Beamline (Kryostaten, Ofen und Vakuumkammer) und die Möglichkeit, sowohl Flach- als auch Kapillarproben untersuchen zu können. de_DE
dc.description.abstract High-resolution powder diffraction experiments at synchrotron radiation sources are expensive and time consuming until now. With the new multiple-detector-system (MDS) at the beamline B2 at HASYLAB (DESY) we have achieved a major breakthrough in increasing the efficiency of the measurements and the expansion of the experimentel options. The MDS - four diffractometers in parallel beam geometry for high-resolution powder diffraction experiments in one compact unit - has a maximum gain factor of approximately 4 according to the net measuring time of conventional diffractometers. Additionally the simultaneously detection of different angular ranges enables an judgement of the data quality already at the running measurement. Using the small divergence of the incident beam the Bragg reflection angles are measured with highest angular resolution and independent of the sample position. The hardware of the MDS is modular designed. Functional units as the simultaneously steping motor drives for the analyser and scintillation counters, individual crystal position units and adjustable lead shields ensure the precise operation of the MDS. The control of the MDS is an integral part of the beamline B2 operating software. All processes are controled by one computer. The uniform software layout enables the user a short training period. The synchronous drives of the four analyser units make time consuming adjustments unnecessary, a significant point of the MDS efficiency. The positioning accuracy of the analyser units is 0.00034°. The modulare system of the analyser units consists in their exchangeable crystal analysers, flat Si(111) crystal analysers and Ge(111) channel-cut crystal analysers. This allows the MDS to work in a wavelength range from 0.6 Å (20.7 keV) to 2.5 Å (4.96 keV). en
dc.language.iso de de_DE
dc.publisher Universität Tübingen de_DE
dc.rights ubt-nopod de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_ubt-nopod.php?la=de de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_ubt-nopod.php?la=en en
dc.subject.classification Synchrotronstrahlung , Strukturanalyse , Effizienz de_DE
dc.subject.ddc 530 de_DE
dc.subject.other Multi-Detektor-System , Hochauflösende Pulverbeugung , de_DE
dc.subject.other Synchrotron radiation , Multiple-detector-system , High resolution powder diffraction , Structure analysis , Efficiency en
dc.title Multi-Detektor-System für das hochauflösende Pulverdiffraktometer B2 am HASYLAB (DESY) - Entwicklung, Aufbau und Einsatz eines zeit-effizienten Messsystems zur Strukturanalyse von Pulverproben mit Synchrotronstrahlung de_DE
dc.title Multiple-detector-system for the high resolution powder X-ray diffractometer B2 at HASYLAB (DESY) - development, design and operation of an highly efficient measuring system for structure analysis of powder data using synchrotron radiation en
dc.type PhDThesis de_DE
dc.date.updated 1970-01-01 de_DE
dcterms.dateAccepted 2001-04-03 de_DE
utue.publikation.fachbereich Sonstige - Mathematik und Physik de_DE
utue.publikation.fakultaet 7 Mathematisch-Naturwissenschaftliche Fakultät de_DE
dcterms.DCMIType Text de_DE
utue.publikation.typ doctoralThesis de_DE
utue.opus.id 238 de_DE
thesis.grantor 12/13 Fakultät für Mathematik und Physik de_DE

Dateien:

Das Dokument erscheint in:

Zur Kurzanzeige