Darstellung und Normwertdefinition der räumlichen und zeitlichen Abfolge von Lippenbewegungen bei Sprachsequenzen durch die elektromagnetische Artikulographie

DSpace Repository

Show simple item record

dc.contributor.advisor Göz, Gernot (Prof. Dr. Dr.) de_DE
dc.contributor.author Koos, Bernd Klaus de_DE
dc.date.accessioned 2008-09-17 de_DE
dc.date.accessioned 2014-03-18T09:40:18Z
dc.date.available 2008-09-17 de_DE
dc.date.available 2014-03-18T09:40:18Z
dc.date.issued 2008 de_DE
dc.identifier.other 285776312 de_DE
dc.identifier.uri http://nbn-resolving.de/urn:nbn:de:bsz:21-opus-35642 de_DE
dc.identifier.uri http://hdl.handle.net/10900/45295
dc.description.abstract Einleitung Die exakten räumlichen und zeitlichen Bewegungen von Lippen sind bislang kaum untersucht. Ihre präzise Darstellung und Analyse ist mit konventionellen Untersuchungsmethoden nicht möglich. Ziel dieser Dissertation war die Aufzeichnung, Darstellung und Analyse von Konsonant-Vokal-Konsonat (CVC) Sprachsequenzen mit anschließender Normwertdefinition für die Lippenbewegungen. Material und Methoden Die Studienpopulation wird von 25 Probanden gebildet, davon 11 männlich und 14 weiblich. Der Median des Durchschnittsalters, zum Zeitpunkt der Untersuchung, lag bei 25,6 Jahren, der Interquartilsabstand betrug 1,4. Der älteste Teilnehmer war 29,1 Jahre und der Jüngste 23,1 Jahre alt. Für die Studie wurden ausschließlich funktionell unauffällige Probanden zugelassen. Die Messungen mit dem Tübinger Artikulographen wurden für die CVC-Sequenzen Mepape, Mepepe, Mepipe, Mepope und Mepupe unter kontrollierten Bedingungen in den verschiedenen Positionen aufrecht und entspannt jeweils 10-mal wiederholt. Ergebnisse Die EMA ist eine präzise und zuverlässige Untersuchungsmethode zur Aufzeichnung von extra- und intraoralen Bewegungen. Der Messfehler bei räumlichen und zeitlichen Variablen war insgesamt sehr klein. Die Position hatte keinen Einfluss auf den Messfehler. Auf die Messwerte konnte ebenfalls kein Einfluss der Position festgestellt werden. Das Geschlecht hingegen, zeigte einen signifikanten Einfluss auf die Messwerte der gesprochenen Sequenzen. Die Messwerte waren gut geeignet, Normwerttabellen für die CVC-Sequenzen zu definieren. Aufgrund des Einflusses des Geschlechts, wurden geschlechtlich getrennte Normwerttabellen definiert. Schlussfolgerung Die EMA zeigte sich als sehr gut für die genaue Erforschung von Lippenbewegungen und deren pathologische Störungen geeignet. Es konnten geschlechtlich getrennten Normwerttabellen definiert werden. Die elektromagnetische Artikulographie ist unter der Vorraussetzung, dass das Verfahren und die Software weiter standardisiert werden, insbesondere für die Diagnostik, Therapiekontrolle und die Verlaufsdokumentation für den Kieferorthopäden, Pädiater und Logopäden ideal geeignet. de_DE
dc.description.abstract Introduction Accurate spatio-temporal movement of lips has hardly been examined so far. Its precise depiction and analysis is not possible by conventional examination methods. Aim of this thesis was to record, depict and analyse consonant-vocal-consonant (CVC) speaking sequences and the consequent definition of norms for lip movement. Material and Methods The study population was comprised of 25 subjects, of whom 11 were male and 14 female. At the time of examination the median age was 25.6 years, the interquartil difference was 1.4. The oldest participant was 29.1 years of age, the youngest 23.1. Only functionally inconspicuous subjects were included in the study. In Tübingen electromagnetic articolography measurements were conducted for the CVC sequences Mepape, Mepepe, Mepipe, Mepope and Mepupe under controlled conditions. Two different sitting positions were applied: upright and relaxed, with 10 repetitions each. Results EMA is a precise and reliable examination method for depicting extra and intraoral movement. The measurement error for spatio-temporal variables was altogether at a minimum. The measuring error was not influenced by the position, neither were the measuring values. On the other hand gender showed a significant influence on the measurement values of the spoken sequences. The measurements were well suitable to define tables with norm values for CVC sequences. Due to the influence of gender, gender-specific norm tables were defined. Conclusions It was shown that EMA is especially suited for the precise study of lip movement and pathologic changes of the latter. Due to significant gender-specific differences separate norm tables were defined. Provided that method and software will be further standardized for use of orthodontist, paediatrician and speech therapist, electromagnetic articulography will be ideally suitable for diagnosis, therapy control and documentation. en
dc.language.iso de de_DE
dc.publisher Universität Tübingen de_DE
dc.rights ubt-podno de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_ohne_pod.php?la=de de_DE
dc.rights.uri http://tobias-lib.uni-tuebingen.de/doku/lic_ohne_pod.php?la=en en
dc.subject.classification Kieferorthopädie , Dissertation , Normalwert , Lippe , Bewegung de_DE
dc.subject.ddc 610 de_DE
dc.subject.other Elektromagnetische Artikulographie , EMA , CVC Sequenzen de_DE
dc.subject.other Electromagnetic articulography , EMA , CVC Sequences en
dc.title Darstellung und Normwertdefinition der räumlichen und zeitlichen Abfolge von Lippenbewegungen bei Sprachsequenzen durch die elektromagnetische Artikulographie de_DE
dc.title Depiction and definition of norms for spatio-temporal courses of lip movement during speaking sequences using electromagnetic articulography en
dc.type PhDThesis de_DE
dcterms.dateAccepted 2006-12-01 de_DE
utue.publikation.fachbereich Sonstige de_DE
utue.publikation.fakultaet 4 Medizinische Fakultät de_DE
dcterms.DCMIType Text de_DE
utue.publikation.typ doctoralThesis de_DE
utue.opus.id 3564 de_DE
thesis.grantor 05/06 Medizinische Fakultät de_DE

Dateien:

This item appears in the following Collection(s)

Show simple item record